Installation and Maintenance

 

INSTALLATION

Koby Air Purifiers and related products are completely disposable and are virtually maintenance free. Units are installed directly to air operated equipment, or to existing air line, using standard NPT pipe fittings. When direct installation to equipment is not possible, install after regulator before air hose.

A general bowl-type air line filter or Koby Mainline Unit should be installed before purifier to remove bulk liquid water and oil. (See Below.) These impurities, if not removed, will greatly impair the adsorption capacity of activated carbon in purifier.
 
General Bowl Type
Air Filter or
Koby Mainline
--—>
Regulator
-—->
Koby
Air Purifier
-—->
Point of Use

WHEN TO REPLACE - General Non-Hazardous Applications

For best results, Koby Air Purifiers, Vacuum Pump In-Line Air Purifiers, Noise Muffler Air Purifiers, and related products, should be replaced according to specified recommended replacement when used to remove oil mist, oil vapor, droplets of oil and water, fine particles and other general contaminants. When used to remove obnoxious odors, tastes, solvent vapors, and similar contaminants, replace immediately when a noticeable odor is detected on purifier discharge. When used only to trap solid particles, pipe scale, rust, sediments, dust, etc., replace every six months from date of installation. To insure proper replacement, record date installed, and when to replace on product label.

WHEN TO REPLACE - Hazardous Applications

When removing dangerous, organic and inorganic contaminants from laboratory compressed air or vacuum air, periodic testing of outward air quality is recommended. Purifiers and related products should be replaced when outward air quality reaches an unacceptable condition or exceeds permissible exposure levels.

SPECIFIC INSTALLATION & MAINTENANCE INSTRUCTIONS

 